Back30 photos
Rampe menant à la porte d'entrée
Buanderie Comptoir de la réception Salle d'entraînement Section boutique Lobby Salle du petit-déjeuner Buffet du petit-déjeuner Salle de toilette femmes Salle de toilette femmes Salle de toilette hommes Chambre 1609 Chambre 1609 Chambre 1609 Chambre 1609 Salle de bain de la chambre 1609 Salle de bain de la chambre 1609 Salle de bain de la chambre 1609 Salle de bain de la chambre 1609 Salle de bain de la chambre 1409 Salle de bain de la chambre 1409 Salle de bain de la chambre 1409 Chambre 1409 Chambre 1409 Chambre 309 Chambre 309 Chambre 309 Salle de bain de la chambre 309 Salle de bain de la chambre 309 Salle de bain de la chambre 309

Marriott Residence Inn Montréal Centre-ville

Hotel

1
View on map
Salle de bain

Salle de bain

  • Clear Width : 60cm
  • Maneuvering area : 91m de largeur x 1,14m de profondeur
  • No transfer zone on the side of the bowl
  • Toilet bowl seat located at a height between 43 cm and 48.5 cm above the floor
  • No grab bar
  • No grab bar
  • No grab bar
  • Maneuvering area in front of the sink : 90cm de largeur x 1cm de profondeur
  • Surface located at a height between 68.5 cm and 86.5 cm above the ground
  • No clearance under the sink
  • Shower with a threshold height of : 7cm
  • Clear area in front of the shower : 90cm x 90cm
  • Clear width of entrance : 59cm
  • Area of : 85cm x 115cm
  • Removable transfer bench available
  • Vertical bar
  • Length : 78cm
  • Lower end located at : 81cm au-dessus du sol
  • No grab bar
  • Horizontal, vertical or oblique bar
  • Length horizontal element : 90cm
  • Horizontal element located between 75 cm and 87 cm above the ground
  • Clear Width : 79cm
  • Maneuvering area at least 1.5 m wide x 1.5 m deep
  • Transfer area on the side of the bowl at least 90 cm wide x 1.5 m deep
  • Horizontal grab bar
  • Length of at least 76 cm
  • Accessible sink
  • Roll-in shower
  • Area of more than 90 cm x 1.5 m
  • Removable transfer bench available
  • Unobstructed area in front of shower exceeds 90 cm x 1.5 m

Exterior Entrance

  • 1 step or more : 3marches
  • Fixed access ramp
  • Free width of at least 87 cm
  • On a gentle slope
  • Handrail on one side only
  • Vestibule at least 1.5 m deep and at least 1.2 m wide
  • Sliding doors

Interior entrance

  • Free width of at least 1.1 m
  • Maneuvering space of at least 1.5 m x 1.5 m
  • Difference in level between the exterior floor covering and the door sill : 2  cm
  • Opening requiring significant physical effort
  • No electric opening mechanism
  • Free width of at least 1.1 m
  • Difference in level between the exterior floor covering and the door sill : 2  cm
  • Restricted clear width
  • Opening requiring significant physical effort
  • No electric opening mechanism

Inside of the establishment*

  • Reception counter too high : 122cm
  • Reception desk: no clearance under the desk
  • Reception desk: manoeuvering space larger than 1.2 m x 1.2 m
  • Narrow elevator : 100cm x 147cm

Accommodation Unit

  • Maneuvering space of at least 1.5 m in diameter
  • Circulation corridor of at least 92 cm
  • Mattress Top : 65cm au-dessus du plancher
  • Clearance under the bed of at least 15 cm
  • Maneuvering area on the side of the bed at least 1.5 m wide x 1.5 m deep
  • Maneuvering space of at least 1.5 m in diameter
  • Circulation corridor of at least 92 cm
  • Top of the mattress between 46 cm and 50 cm above the floor
  • Clearance under the bed of at least 15 cm
  • Desk surface located between 68.5 cm and 86.5 cm above the floor
  • Clearance under the desk of at least 68.5 cm above the floor
  • 2 beds
  • Double bed
  • Transfer zone on side of bed exceeds 92 cm

Room*

  • Access to room: path of travel exceeds 1.1 m
  • Clear width of room door restricted (between 76 and 79 cm)
  • Manoeuvring space in room exceeds 1.5 m x 1.5 m
  • Transfer zone on side of bed exceeds 92 cm
  • King-size bed
  • Bed: top of mattress between 46 cm and 50 cm
  • Bed: clearance under bed
  • Desk: height between 68.5 cm and 86.5 cm
  • Desk: clearance under desk exceeds 68.5 cm

Bathroom*

  • Clear width of bathroom door restricted (between 76 and 79 cm)
  • Surface area of bathroom  : 2,20m x 1,90m
  • Manoeuvring space in bathroom exceeds 1.5 m x 1.5 m
  • Toilet bowl too far from the wall : 43cm
  • Larger than 87.5 cm clear floor space on the side of the toilet bowl
  • Toilet seat height: between 40 cm and 46 cm
  • Horizontal grab bar at left of the toilet: too low : 78cm
  • Horizontal grab bar at left of the toilet height: between 84 cm and 92 cm
  • Sink height: between 68.5 cm and 86.5 cm
  • Clearance under the sink: larger than 68.5 cm
  • clear space area in front of the sink larger than 80 cm x 1.2 m
  • Roll-in shower (shower without sill)
  • Unobstructed area in front of shower exceeds 90 cm x 1.5 m
  • Shower: clear width of entrance exceeds 1 m
  • Shower: surface area exceeds 90 cm x 1.5 m
  • Shower: removable transfer bench available
  • Shower: grab bar on back wall: horizontal
  • Shower: grab bar on back wall: exceeds 90 cm in length
  • Shower: grab bar on back wall between 70 cm and 80 cm in length
  • Shower: grab bar near faucets: vertical
  • Shower: length of grab bar near faucets insufficient : 75cm
  • Shower: grab bar near faucets between 70 cm and 80 cm

Washrooms with multiple stalls*

  • Manoeuvring space larger than 1.5 m x 1.5 m in front of the toilet room
  • Sink height: between 68.5 cm and 86.5 cm
  • Inadequate clearance under the sink : 66,5cm
  • clear space area in front of the sink larger than 80 cm x 1.2 m
  • Sink: faucets with sensor
  • Accessible toilet stall: space larger than 1.5 m x 1.5 m : 1,96m x 1,65m
  • Accessible toilet stall: manoeuvring space larger tham 1.2 mx 1.2 m
  • Accessible toilet stall: more than 87.5 cm of clear space area on the side
  • Accessible toilet stall: horizontal grab bar at the left
  • Accessible toilet stall: horizontal grab bar behind the toilet located between 84 cm and 92 cm from the ground
  • Passageway for accessing to toilet room larger than 1,1 m
  • Manoeuvring space larger than 1.5 m x 1.5 m in front of the toilet room
  • Sink height: between 68.5 cm and 86.5 cm
  • Inadequate clearance under the sink : 66,5cm
  • clear space area in front of the sink larger than 80 cm x 1.2 m
  • Sink: faucets with sensor
  • Narrow accessible toilet stall : 1,46m x 1,68m
  • Accessible toilet stall: narrow manoeuvring space : m x m
  • Accessible toilet stall: toilet bowl far from the wall : cm
  • Accessible toilet stall: narrow clear space area on the side : cm
  • Accessible toilet stall: horizontal grab bar at the left
  • Accessible toilet stall: horizontal grab bar behind the toilet located between 84 cm and 92 cm from the ground

Food service*

  • Table height: between 68.5 cm and 86.5 cm
  • Inadequate clearance under the table
  • Buffet too high : 87cm
  • No clearance under the buffet