Back25 photos
Rampe entrée extérieure
Entrée extérieure Rampe d'accès piscine Gym Piscine Panneau de commandes de l'ascenseur Lobby Espace commun 3e étage Comptoir réception Intérieur ascenseur Espace commun 3e étage Commerce libre-service Salle de bain chambre 1505 Vanité chambre 1505 Chambre 1505 Penderie Bureau chambre 1505 Toilette chambre 1505 Douche chambre 1505 Chambre 1505 Toilette femme 3e étage Salle de toilettes femme 3e étage Salle de toilettes hommes 3e étage Toilette homme 3e étage Porte d'entrée

Westin Montréal

Hotel

2
View on map
270, rue Saint-Antoine Ouest, Montréal, H2Y 0A3, Québec
514-380-3333

Exterior Entrance

  • Circulation corridor at least 1.1 m wide
  • Accessible driveway leading to the entrance
  • 1 step or more : 3marches
  • Fixed access ramp
  • Free width of at least 87 cm
  • Accessible handrail
  • Maneuvering area on each side of the door at least 1.5 m wide x 1.5 m deep
  • Free width of at least 80 cm
  • Opening requiring significant physical effort
  • No electric opening mechanism
Salle de bain

Salle de bain

  • Maneuvering area on each side of the door at least 1.5 m wide x 1.5 m deep
  • Free width of at least 80 cm
  • Maneuvering area at least 1.5 m wide x 1.5 m deep
  • Transfer zone on the side of the bowl : 71cm de largeur x 1,5m de profondeur
  • Maneuvering area in front of the sink at least 80 cm wide x 1.2 m deep
  • Roll-in shower
  • Clear width of entrance : cm
  • Shower with door
  • Area of : 86cm x 1,48cm
  • Removable transfer bench available
  • Vertical bar
  • Horizontal, oblique or L-shaped bar
  • Horizontal, vertical or oblique bar
Stationnement

Parking

  • Interior

Interior entrance

  • Free width of at least 1.1 m
  • Maneuvering space of at least 1.5 m x 1.5 m
  • Free width of at least 80 cm
  • Opening requiring significant physical effort

Interior of the building

  • Accessible elevator
  • Maneuvering space at least 1.5 m wide x 1.5 m deep located in front of the door
  • Dimension of at least 1.37 m wide x 2.03 m deep
  • Counter surface : 87,3cm au-dessus du plancher
  • Clearance under the counter of at least 68.5 cm
  • Fixed payment terminal : 120cm au-dessus du plancher

Accommodation Unit

  • Maneuvering space of at least 1.5 m in diameter
  • Circulation corridor of at least 92 cm
  • Mattress Top : 70cm au-dessus du plancher
  • Clearance under the bed of at least 15 cm
  • 1 bed
  • King-size bed
  • Transfer zone on side of bed exceeds 92 cm

Washroom

  • Circulation corridor at least 1.1 m wide
  • Difference in level between the exterior floor covering and the door sill : 3cm
  • Free width of at least 80 cm
  • Opening requiring significant physical effort
  • Maneuvering space in front of the washbasin at least 80 cm wide x 120 cm deep
  • Clearance depth under sink : 20cm
  • Maneuvering space in front of the urinal at least 80 cm wide x 120 cm deep
  • No grab bar
  • Dimension of at least 1.5 m wide x 1.5 m deep
  • Indoor maneuvering space at least 1.2 m wide x 1.2 m deep inside
  • Free width of the door at least 85 cm
  • Transfer area on the side of the toilet bowl : 75,6cm
  • Horizontal to the right of the bowl
  • Horizontal behind the bowl
  • Circulation corridor at least 1.1 m wide
  • single door
  • Difference in level between the exterior floor covering and the door sill : 3cm
  • Free width of at least 80 cm
  • Maneuvering space in front of the washbasin at least 80 cm wide x 120 cm deep
  • Clearance depth under sink : 20cm
  • Dimension of at least 1.5 m wide x 1.5 m deep
  • Indoor maneuvering space at least 1.2 m wide x 1.2 m deep inside
  • Free width of the door at least 85 cm
  • Transfer area on the side of the toilet bowl : 81cm
  • Horizontal to the right of the bowl
  • Horizontal behind the bowl

Swimming pool*

  • Access to swimming pool: entrance located inside building
  • Swimming pool: no equipment adapted for disabled persons
  • Access to swimming pool: manoeuvring space in front of access ramp exceeds 1.5 m x 1.5 m